Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Radiat Oncol ; 19(1): 50, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637844

RESUMO

BACKGROUND: Stereotactic ablative radiotherapy (SABR) is the standard treatment for medically inoperable early-stage non-small cell lung cancer (ES-NSCLC), but which patients benefit from stereotactic radiotherapy is unclear. The aim of this study was to analyze prognostic factors for early mortality. METHODS: From August 2010 to 2022, 617 patients with medically inoperable, peripheral or central ES-NSCLC were treated with SABR at our institution. We retrospectively evaluated the data from 172 consecutive patients treated from 2018 to 2020 to analyze the prognostic factors associated with overall survival (OS). The biological effective dose was > 100 Gy10 in all patients, and 60 Gy was applied in 3-5 fractions for a gross tumor volume (GTV) + 3 mm margin when the tumor diameter was < 1 cm; 30-33 Gy was delivered in one fraction. Real-time tumor tracking or an internal target volume approach was applied in 96% and 4% of cases, respectively. In uni- and multivariate analysis, a Cox model was used for the following variables: ventilation parameter FEV1, histology, age, T stage, central vs. peripheral site, gender, pretreatment PET, biologically effective dose (BED), and age-adjusted Charlson comorbidity index (AACCI). RESULTS: The median OS was 35.3 months. In univariate analysis, no correlation was found between OS and ventilation parameters, histology, PET, or centrality. Tumor diameter, biological effective dose, gender, and AACCI met the criteria for inclusion in the multivariate analysis. The multivariate model showed that males (HR 1.51, 95% CI 1.01-2.28; p = 0.05) and AACCI > 5 (HR 1.56, 95% CI 1.06-2.31; p = 0.026) were significant negative prognostic factors of OS. However, the analysis of OS showed that the significant effect of AACCI > 5 was achieved only after 3 years (3-year OS 37% vs. 56%, p = 0.021), whereas the OS in one year was similar (1-year OS 83% vs. 86%, p = 0.58). CONCLUSION: SABR of ES-NSCLC with precise image guidance is feasible for all medically inoperable patients with reasonable performance status. Early deaths were rare in our real-life cohort, and OS is clearly higher than would have been expected after best supportive care.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Carcinoma de Pequenas Células do Pulmão , Masculino , Humanos , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Estudos de Coortes , Estudos Retrospectivos , Estadiamento de Neoplasias , Análise de Sobrevida , Carcinoma de Pequenas Células do Pulmão/patologia , Radiocirurgia/métodos , Resultado do Tratamento
2.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38306687

RESUMO

AIMS: Data on the hybrid atrial fibrillation (AF) treatment are lacking in patients with structural heart disease undergoing concomitant CryoMaze procedures. The aim was to assess whether the timely pre-emptive catheter ablation would achieve higher freedom from AF or atrial tachycardia (AT) and be associated with better clinical outcomes than surgical ablation alone. METHODS AND RESULTS: The trial investigated patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement with mandatory concomitant CryoMaze procedure who were randomly assigned to undergo either radiofrequency catheter ablation [Hybrid Group (HG)] or no further treatment (Surgery Group). The primary efficacy endpoint was the first recurrence of AF/AT without class I or III antiarrhythmic drugs as assessed by implantable cardiac monitors. The primary clinical endpoint was a composite of hospitalization for arrhythmia recurrence, worsening of heart failure, cardioembolic event, or major bleeding. We analysed 113 and 116 patients in the Hybrid and Surgery Groups, respectively, with a median follow-up of 715 (IQR: 528-1072) days. The primary efficacy endpoint was significantly reduced in the HG [41.1% vs. 67.4%, hazard ratio (HR) = 0.38, 95% confidence interval (CI): 0.26-0.57, P < 0.001] as well as the primary clinical endpoint (19.9% vs. 40.1%, HR = 0.51, 95% CI: 0.29-0.86, P = 0.012). The trial groups did not differ in all-cause mortality (10.6% vs. 8.6%, HR = 1.17, 95%CI: 0.51-2.71, P = 0.71). The major complications of catheter ablation were infrequent (1.9%). CONCLUSION: Pre-emptively performed catheter ablation after the CryoMaze procedure was safe and associated with higher freedom from AF/AT and improved clinical outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Resultado do Tratamento , Taquicardia Supraventricular/cirurgia , Antiarrítmicos/uso terapêutico , Hemorragia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
3.
J Appl Biomed ; 21(2): 67-72, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37212155

RESUMO

BACKGROUND: Atrial fibrillation is common in patients with structural heart disease who are undergoing cardiac surgery. Surgical CryoMaze has been shown to be an effective treatment in several trials, but success rates have varied considerably, between 47-95%. The sequential hybrid approach, combining surgical CryoMaze followed by radiofrequency catheter ablation, can achieve high freedom from atrial arrhythmias. However, in patients with concomitant surgical atrial fibrillation treatment, data comparing the hybrid approach to CryoMaze alone are lacking. METHODS: The SurHyb study was designed as a prospective, open-label, multicentre randomized trial. Patients with non-paroxysmal atrial fibrillation who were scheduled for coronary artery bypass grafting or valve repair/replacement were randomized to either surgical CryoMaze alone or surgical CryoMaze followed by radiofrequency catheter ablation 3 months post-surgery. The primary outcome measure was arrhythmia-free survival without class I or III antiarrhythmic drugs, which has been evaluated using implantable cardiac monitors. CONCLUSIONS: This is the first randomized study that compares concomitant surgical CryoMaze alone with the staged hybrid surgical CryoMaze followed by catheter ablation, in patients with non-paroxysmal atrial fibrillation using rigorous rhythm monitoring. The results may contribute to the optimization of the treatment in patients undergoing concomitant CryoMaze for atrial fibrillation.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Ablação por Cateter , Humanos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Procedimentos Cirúrgicos Cardíacos/métodos , Ablação por Cateter/métodos , Estudos Multicêntricos como Assunto , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
4.
Cancers (Basel) ; 15(4)2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36831416

RESUMO

Unnafected female carriers of BRCA1 and BRCA2 pathogenic/likely pathogenic variants (P/LPVs) are at higher risk of breast cancer (BC) and ovarian cancer (OC). In the retrospective single-institution study in the Czech Republic, we analyzed the rate, longitudinal trends, and effectiveness of prophylactic risk-reducing mastectomy (RRM) and risk-reducing salpingo-oophorectomy (RRSO) on the incidence of BC and OC in BRCA1/2 carriers diagnosed between years (y) 2000 to 2020. The study included 496 healthy female BRCA1/2 carriers. The median follow-up was 6.0 years. RRM was performed in 156 (31.5%, mean age 39.3 y, range 22-61 y) and RRSO in 234 (47.2%, mean age 43.2 y, range 28-64 y) BRCA1/2 carriers. A statistically significant increase of RRM (from 12% to 29%) and RRSO (from 31% to 42%) was observed when comparing periods 2005-2012 and 2013-2020 (p < 0.001). BC developed in 15.9% of BRCA1/2 carriers without RRM vs. 0.6% of BRCA1/2 carriers after RRM (HR 20.18, 95% CI 2.78- 146.02; p < 0.001). OC was diagnosed in 4.3% vs. 0% of BRCA1/2 carriers without vs. after RRSO (HR not defined due to 0% occurrence in the RRSO group, p < 0.001). Study results demonstrate a significant increase in the rate of prophylactic surgeries in BRCA1/2 healthy carriers after 2013 and the effectiveness of RRM and RRSO on the incidence of BC and OC in these populations.

5.
Radiat Oncol ; 9: 192, 2014 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-25175267

RESUMO

BACKGROUND: To evaluate pancreatic tumor motion and its dynamics during respiration. METHODS AND MATERIALS: This retrospective study includes 20 patients with unresectable pancreatic cancer who were treated with stereotactic ablative radiotherapy. An online respiratory tumor tracking system was used. Periodical maximum and minimum tumor positions with respiration in superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were collected for tumor motion evaluation. The predictability of tumor motion in each axis, based on reference measurement, was analyzed. RESULTS: The use of a 20-mm and 5-mm constant margins for SI and LL/AP directions, avoids target underdosage, without the need for reference measurement. Pearson's correlation coefficient indicated only a modest correlation between reference and subsequent measurements in the SI direction (r = 0.50) and no correlation in LL (r = 0.17) and AP (r = 0.35) directions. When margins based on the reference measurement of respiratory tumor motion are used, then 30% of patients have a risk zone of underdosage >3 mm (in average). ITV (internal target volume) optimization based on the reference measurement is possible, but allows only modest margin reduction (approximately from 20 mm to 16-17 mm) in SI direction and no reduction in AP and LL directions. CONCLUSION: Our results support the use of 20-mm margin in the SI direction and 5-mm margins in the LL and AP directions to account for respiratory motion without reference measurement. Single measurement of tumor motion allows only modest margin reduction. Further margin reduction is only possible when there is on-line tumor motion control according to internal markers.


Assuntos
Artefatos , Carcinoma/cirurgia , Neoplasias Pancreáticas/cirurgia , Planejamento da Radioterapia Assistida por Computador/métodos , Respiração , Feminino , Humanos , Masculino , Movimento (Física) , Radiocirurgia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA